Analytical method for the determination of diethyl sulfate

Translation of DGUV Information 213-518 (former BGI 505-18 or ZH1/120.18)

CAS Number: 64-67-5

Synonyms:

  • DES
  • Sulfuric acid diethyl ester

Method 05 – GC/MS after thermal desorption – limited suitability: category E3

Sampling is carried out with a pump and adsorption on Tenax. Analysis is performed by gas chromatography with mass selective detection (GC/MS) after thermal desorption. 

This method can be used with personal or stationary sampling to determine the mean concentration of diethyl sulfate at workplaces over the sampling time.

Principle

A pump draws a defined volume of air through a metal tube filled with Tenax. The adsorbed diethyl sulfate is then thermally desorbed and determined by gas chromatography.

Limit of quantification (LOQ)

Absolute: 78 ng of diethyl sulfate

Relative: 3 µg/m³ of diethyl sulfate for a 25 L air sample.

Issue

February 2007

The measuring method is of limited suitability (E3).

The complete measuring method is available in the Wiley Online Library: Method for the determination of diethyl sulfate (Air Monitoring Methods, Volume 12, 2011).


Method 04 – GC – limited suitability: category E3

Sampling with a pump, adsorption on Tenax-TA, desorption, gas chromatography and mass-selective detection 

This method permits the determination of diethyl sulfate concentrations in working areas averaged over the sampling time after personal or stationary sampling.

Principle

With a pump a measured air volume is drawn through a Tenax tube. The adsorbed diethyl sulfate is desorbed with toluene and analysed using a gas chromatograph with mass selective detector.

Limit of quantification (LOQ)

Absolute: 0,4 ng diethyl sulfate.

Relative: 0.01 mg/m3 diethyl sulfate for 20 L air sample, 1 mL of desorption solution and 2 µL injection volume.

Issue

April 1997

The measuring method is of limited suitability (E3).

The complete measuring method is available in the Wiley Online Library: Method for the determination of diethyl sulfate (Analyses of Hazardous Substances in Air, Volume 5, 2002).


Method 03 – GC – withdrawn

Sampling with a pump, adsorption on Tenax-TA, desorption, gas chromatography and mass-selective detection 

This method is carried out in the same way as described for dimethyl sulfate (Translation of DGUV Information 213-507).

Issue

January 1987

Withdrawn

December 2005


Method 02 – GC – withdrawn

Sampling with a pump, adsorption on silica gel, desorption, gas chromatography and sulfur-specific detection 

This method is carried out in the same way as described for dimethyl sulfate (Translation of DGUV Information 213-507).

Issue

December 1983

Withdrawn

December 2005


Method 01 – GC – withdrawn

Sampling with a pump, adsorption on Tenax-TA, desorption, gas chromatography and sulfur-specific detection 

This method is carried out in the same way as described for dimethyl sulfate (Translation of DGUV Information 213-507).

Issue

December 1983

Withdrawn

December 2005