Analytical method for the determination of 2-nitronaphthalene
Translation of DGUV Information 213-522 (former BGI 505-22 or ZH1/120.22)
CAS Number: 581-89-5
Method 02 – HPLC – limited suitability: category E3
Sampling is carried out with a pump, the particulate fraction being collected on a glass fiber filter and the gaseous fraction adsorbed on a connected silica gel tube. Analysis is performed by high-performance liquid chromatography (HPLC) after desorption.
This method permits the determination of the 2-nitronaphthalene concentration at workplaces averaged over the sampling time after personal or stationary sampling.
Principle
A pump draws a defined volume of air through a GSP sampling system equipped with a glass fiber filter and a silica gel tube. The collected 2-nitronaphthalene is desorbed with methanol and analysed by means of liquid chromatography.
Limit of quantification (LOQ)
Absolute: 3 ng of 2-nitronaphthalene.
Relative: 3.8 µg/m3 of 2-nitronaphthalene for an air sample volume of 240 L, a sample solution of 3 mL and an injection volume of 10 µL.
Issue
April 2008
The measuring method is of limited suitability (E3).
The complete measuring method is available in the Wiley Online Library: Method for the determination of 2-nitronaphthaline (Air Monitoring Methods, Volume 13, 2012).
Method 01 – GC – withdrawn
Sampling with a pump and adsorption on silica gel, gas chromatography after desorption.
This method permits the determination of the 2-nitronaphthalene concentration at workplaces averaged over the sampling time after personal or stationary sampling.
Principle
With a pump a measured air volume is drawn through tubes filled with silica gel. The adsorbed 2-nitronaphthalene is then desorbed with methanol and determined by gas chromatography.
Limit of quantification (LOQ)
Absolute: 2 ng of 2-nitronaphthalene.
Relative: 0.05 mg/m³ ≙ 0.007 ml/m³ (ppm) 2-nitronaphthalene for a 40-litre air sample.
Issue
December 1983
Withdrawn
February 2007