Analytical method for the determination of N-nitrosamines

Translation of DGUV Information 213-523 (former BGI 505-23 or ZH1/120.23)

IUPAC Name CAS Number
N-Nitrosodimethylamine 62-57-9
N-Nitrosomethylethylamine 10595-95-6
N-Nitrosodiethylamine 55-18-5
N-Nitrosodi-n-propylamine 621-64-7
N-Nitrosodiisopropylamine 601-77-4
N-Nitrosodibutylamine 924-16-3
N-Nitrosopiperidine 100-75-4
N-Nitrosopyrrolidine 930-55-2
N-Nitrosomorpholine 59-89-2

A valid analytical method for the determination of N-nitrosamines is currently only available in German.

Go to the German-language article.


Method 04 – GC – withdrawn

Sampling with a pump and adsorption on a solid collection phase, capillary gas chromatography after elution. 

This method permits the determination of N-nitrosamines concentrations in working areas averaged over the sampling time after personal or stationary sampling.

Principle

With a pump a measured air volume is drawn through an adsorption tube. After elution with a dichloromethane/methanol mixture the adsorbed N-nitrosamines are analysed using a gas chromatograph equipped with a thermal energy analyser (TEA) detector.

Limit of quantification (LOQ)

N-Nitrosamine absolute (ng) relative (µg/m³)
for 200 L air sample, 1 mL sample solution,
5 μL injection volume
N-Nitrosodimethylamine 0.019 0.03
N-Nitrosomethylethylamine 0.021 0.03
N-Nitrosodiethylamine 0.023 0.04
N-Nitrosodi-n-propylamine 0.036 0.06
N-Nitrosodiisopropylamine 0.032 0.05
N-Nitrosodibutylamine 0.051 0.08
N-Nitrosopiperidine 0.028 0.05
N-Nitrosopyrrolidine 0.028 0.05
N-Nitrosomorpholine 0.037 0.06

Issue

September 1992 

Withdrawn

November 2018

The complete measuring method is available in the Wiley Online Library: Method for the determination of N-nitrosamines (Analyses of Hazardous Substances in Air, Volume 4, 1999).


Method 03 – GC – withdrawn

Sampling with a pump and adsorption on a solid collection phase, gas chromatography after elution. 

This method permits the determination of N-nitrosamines concentrations in working areas averaged over the sampling time after personal or stationary sampling.

Principle

With a pump a measured air volume is drawn through an adsorption tube. After elution with a dichloromethane/methanol mixture the adsorbed N-nitrosamines are analysed using a gas chromatograph equipped with a thermal energy analyser (TEA) detector.

Limit of quantification (LOQ)

N-Nitrosamine absolute (ng) relative (µg/m³)
for 200 L air sample, 1 mL sample solution,
5 μL injection volume
N-Nitrosodimethylamine 0.1 0.1
N-Nitrosomethylethylamine 0.1 0.1
N-Nitrosodiethylamine 0.1 0.1
N-Nitrosodi-n-propylamine 0.1 0.1
N-Nitrosodiisopropylamine 0.1 0.1
N-Nitrosodibutylamine 0.2 0.2
N-Nitrosopiperidine 0.1 0.1
N-Nitrosopyrrolidine 0.2 0.2
N-Nitrosomorpholine 0.2 0.2

Issue

September 1992 

Withdrawn

November 2018

The complete measuring method is available in the Wiley Online Library: Method for the determination of N-nitrosamines (Analyses of Hazardous Substances in Air, Volume 4, 1999).

You can reach the German-language version of the article with a single click on the flag-symbol.