Analytical method for the determination of 1,2-epoxybutane

Translation of DGUV Information 213-556 (former BGI 505-56 or ZH1/120.56)

CAS Number: 106-88-7

Synonyms: 

  • 1,2-Butylene oxide
  • Ethyloxirane

Method 03 – Headspace GC/MS

Sampling is carried out with a pump and adsorption on charcoal. Analysis is performed by headspace gas chromatography with mass selective detection (GC/MS).

This method can be used with personal or stationary sampling to determine the mean concentration of 1,2-epoxybutane (1,2-butylene oxide) at workplaces over the sampling time.

Principle

A pump draws a defined volume of air through a glass tube filled with charcoal. The adsorbed 1,2-epoxybutane is desorbed with a mixture of N,N-dimethylacetamide/ water (water content approx. 20% by volume). The analytical determination is achieved by headspace gas chromatography and detection with a mass selective detector.

Limit of quantification (LOQ)

Relative: 0.15 mg/m3 of 1,2-epoxybutane based on a 6 L air sample, 5 mL sample solution and an injection volume of 0.5 mL from the headspace.

Issue

February 2007 

The complete measuring method is available in the Wiley Online Library: Method for the determination of 1,2-epoxybutane (1,2-butylene oxide) (Air Monitoring Methods, Volume 12, 2011).


Method 02 – GC – limited suitability: category E2

Sampling with a pump and adsorption on activated carbon, gas chromatography after desorption.

This method permits the determination of 1,2-epoxybutane concentrations in working areas averaged over the sampling time after personal or stationary sampling.

Principle

With a pump a measured air volume is drawn through a glass tube filled with activated carbon. The adsorbed 1,2-epoxybutane is then desorbed with a mixture of dichloromethane/carbon disulfide/methanol and determined by gas chromatography.

Limit of quantification (LOQ)

Absolute: 8 ng 1,2-epoxybutane.

Relative: 0.5 mg/m3 1,2-epoxybutane for a 20 litre air sample, 2.5 mL of desorption solution and 2 µL injection volume.

Issue

November 1994

The measuring method is of limited suitability (E2).

The complete measuring method is available in the Wiley Online Library: Method for the determination of 1,2-epoxybutane (1,2-butylene oxide) (Analyses of Hazardous Substances in the Air, Volume 7, 2003).


Method 01 – GC

Sampling with a pump and adsorption on polymeric resin Amberlite XAD-4, gas chromatography after thermal desorption.

This method permits the determination of 1,2-epoxybutane concentrations in working areas averaged over the sampling time after personal or stationary sampling.

Principle

With a pump a measured air volume is drawn through a metal tube filled with XAD-4. The adsorbed 1,2-epoxybutane is then desorbed by heating in a thermal desorber and determined by gas chromatography.

Limit of quantification (LOQ)

Absolute: 20 ng 1,2-epoxybutane per adsorption tube.

Relative: 0.1 mg/m3 1,2-epoxybutane for a 200 mL air sample.

Issue

November 1994 

The complete measuring method is available in the Wiley Online Library: Method for the determination of 1,2-epoxybutane (1,2-butylene oxide) (Analyses of Hazardous Substances in the Air, Volume 7, 2003).

You can reach the German-language version of the article with a single click on the flag-symbol.