Analytical method for the determination of α,α-dichlorotoluene
Translation of DGUV Information 213-542 (former BGI 505-42 or ZH1/120.42)
CAS Number: 98-87-3
Synonym: Benzal chloride
Method 02 – GC – limited suitability: category E3
Sampling with a pump and adsorption on Tenax. Gas chromatography after desorption.
This method permits the determination of α,α-dichlorotoluene concentrations in working areas averaged over the sampling time after personal or stationary sampling.
Principle
With a pump a measured air volume is drawn through a Tenax tube. The adsorbed α,α-dichlorotoluene is then desorbed with n-hexane and determined by gas chromatography.
Limit of quantification (LOQ)
Absolute: 0.5 ng α,α-dichlorotoluene.
Relative: 0.01 mg/m³ α,α-dichlorotoluene for 48 L air sample, 1 mL desorption solution and 1 µL injection volume.
Issue
December 1996
The measuring method is of limited suitability (E3).
The complete measuring method is available in the Wiley Online Library: Method for the determination of α,α-dichlorotoluene (Analyses of Hazardous Substances in Air, Volume 5, 2002).
Method 01 – GC – withdrawn
Sampling with a pump and adsorption on activated carbon. Gas chromatography after desorption.
This method permits the determination of α,α-dichlorotoluene concentrations in working areas averaged over the sampling time after personal or stationary sampling.
Principle
With a pump a measured air volume is drawn through a glass tube filled with activated carbon. The adsorbed α,α-dichlorotoluene is then desorbed with carbon disulfide and determined by gas chromatography.
Limit of quantification (LOQ)
Absolute: 0.2 ng α,α-dichlorotoluene.
Relative: 0.01 mg/m³ ≙ 0.0015 mL/m³ (ppm) α,α-dichlorotoluene for 20 L air sample, 1 mL desorption solution and 1 µl injection volume.
Issue
March 1989
Withdrawn
September 2014
The complete measuring method is available in the Wiley Online Library: Method for the determination of α,α-dichlorotoluene (Analyses of Hazardous Substances in Air, Volume 5, 2002).